<?xml version="1.0"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
	<id>https://en.formulasearchengine.com/index.php?action=history&amp;feed=atom&amp;title=Hodge_bundle</id>
	<title>Hodge bundle - Revision history</title>
	<link rel="self" type="application/atom+xml" href="https://en.formulasearchengine.com/index.php?action=history&amp;feed=atom&amp;title=Hodge_bundle"/>
	<link rel="alternate" type="text/html" href="https://en.formulasearchengine.com/index.php?title=Hodge_bundle&amp;action=history"/>
	<updated>2026-05-22T20:10:45Z</updated>
	<subtitle>Revision history for this page on the wiki</subtitle>
	<generator>MediaWiki 1.43.0-wmf.28</generator>
	<entry>
		<id>https://en.formulasearchengine.com/index.php?title=Hodge_bundle&amp;diff=266081&amp;oldid=prev</id>
		<title>en&gt;Brirush at 12:25, 25 November 2014</title>
		<link rel="alternate" type="text/html" href="https://en.formulasearchengine.com/index.php?title=Hodge_bundle&amp;diff=266081&amp;oldid=prev"/>
		<updated>2014-11-25T12:25:51Z</updated>

		<summary type="html">&lt;p&gt;&lt;/p&gt;
&lt;a href=&quot;https://en.formulasearchengine.com/index.php?title=Hodge_bundle&amp;amp;diff=266081&amp;amp;oldid=25252&quot;&gt;Show changes&lt;/a&gt;</summary>
		<author><name>en&gt;Brirush</name></author>
	</entry>
	<entry>
		<id>https://en.formulasearchengine.com/index.php?title=Hodge_bundle&amp;diff=25252&amp;oldid=prev</id>
		<title>en&gt;Bender235: /* References */ navbox</title>
		<link rel="alternate" type="text/html" href="https://en.formulasearchengine.com/index.php?title=Hodge_bundle&amp;diff=25252&amp;oldid=prev"/>
		<updated>2012-06-08T22:08:51Z</updated>

		<summary type="html">&lt;p&gt;&lt;span class=&quot;autocomment&quot;&gt;References: &lt;/span&gt; navbox&lt;/p&gt;
&lt;p&gt;&lt;b&gt;New page&lt;/b&gt;&lt;/p&gt;&lt;div&gt;&amp;#039;&amp;#039;&amp;#039;Interference reflection microscopy or IRM&amp;#039;&amp;#039;&amp;#039; is an optical microscopy technique that utilizes [[Polarization (waves)|polarized light]] to form an image of an object on a glass surface. The [[Luminous intensity|intensity]] of the signal is a measure of proximity of the object to the glass surface. This technique can be used to study events at the cell membrane without the use of a (fluorescent) label in contrast to [[Total internal reflection|TIRF microscopy]].&lt;br /&gt;
&lt;br /&gt;
==History==&lt;br /&gt;
The method was first used for the studying of thin films of oil.&amp;lt;ref&amp;gt;{{cite journal |author=Filler TJ, Peuker ET |title=Reflection contrast microscopy (RCM): a forgotten technique? |journal=The Journal of Pathology |volume=190 |issue=5 |pages=635–8 |year=2000 |month=April |pmid=10727991 |doi=10.1002/(SICI)1096-9896(200004)190:5&amp;lt;635::AID-PATH571&amp;gt;3.0.CO;2-E}}&amp;lt;/ref&amp;gt;&amp;lt;ref&amp;gt;{{cite journal |author=Vašíček A |month=August |year=1961 |title=Theory of Light Reflection From a Thin Absorbing Film Deposited on a Metal |journal=Optics and Spectroscopy |volume=11 |pages=128 |bibcode=1961OptSp..11..128V}}&amp;lt;/ref&amp;gt; In 1964, the first application of the technique in cell biology was introduced by Curtis to study embryonic chick heart fibroblasts.&amp;lt;ref name=&amp;quot;Curtis1964&amp;quot;&amp;gt;{{cite journal |author=Curtis AS |title=THE MECHANISM OF ADHESION OF CELLS TO GLASS : A Study by Interference Reflection Microscopy |journal=The Journal of Cell Biology |volume=20 |issue= 2|pages=199–215 |year=1964 |month=February |pmid=14126869 |pmc=2106393 |doi=10.1083/jcb.20.2.199}}&amp;lt;/ref&amp;gt; He used IRM to look at adhesion sites and distances of fibroblasts, noting that contact with the glass was mostly limited to the cell periphery and the [[pseudopod]]ia.&amp;lt;ref name=&amp;quot;Curtis1964&amp;quot;/&amp;gt;&lt;br /&gt;
&lt;br /&gt;
The technique was refined and the qualitative and quantitative aspects of the technique were later described by several researchers in the 70s and 80s:&amp;lt;ref name=&amp;quot;Verschueren1985&amp;quot;&amp;gt;{{cite journal |author=Verschueren H |title=Interference reflection microscopy in cell biology: methodology and applications |journal=Journal of Cell Science |volume=75 |issue= 1|pages=279–301 |year=1985 |month=April |pmid=3900106 |url=http://jcs.biologists.org/cgi/pmidlookup?view=long&amp;amp;pmid=3900106}}&amp;lt;/ref&amp;gt; Bereiter-Hahn and his colleagues correlated the technique with [[electron microscopy]], showing that different mammalian cell lines adhere to the glass substrate in specific focal adhesion sites.&amp;lt;ref name=&amp;quot;Bereiter1979&amp;quot;&amp;gt;{{cite journal |author=Bereiter-Hahn J, Fox CH, Thorell B |title=Quantitative reflection contrast microscopy of living cells |journal=The Journal of Cell Biology |volume=82 |issue=3 |pages=767–79 |year=1979 |month=September |pmid=389938 |pmc=2110483 |url=http://www.jcb.org/cgi/pmidlookup?view=long&amp;amp;pmid=389938 |doi=10.1083/jcb.82.3.767}}&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
==Theory==&lt;br /&gt;
[[Image:IRM Interference Reflection Microscopy.svg|thumb|500px|alt=Principle of Interference Reflection Microscopy (IRM)|&amp;#039;&amp;#039;&amp;#039;Fig. 1&amp;#039;&amp;#039;&amp;#039;: Principle of Interference Reflection Microscopy (IRM) showing interference effect on reflected waves and the result on the final image intensity. Dark purple wave represents the light from the light source. The light purple waves are the reflections from the cell membrane and from the glass surface. Upon hitting the glass surface, the reflected waves are shifted half a wavelength. When the membrane is very close to the glass, the reflected light will be reflected out of phase with the reflected beam from the glass. This will cause interference (see red line), resulting in a dark pixel. If there is more distance between the membrane and the glass, the returning waves will be less shifted and won&amp;#039;t cause interference (see red line), resulting in a brighter pixel in the final image. Indicated are the typical refractive indices of the glass, medium and the cell membrane, which determine the amount of reflection.]]&lt;br /&gt;
&lt;br /&gt;
In order to form an image of the attached cell, light of a specific [[wavelength]] is passed through a [[polarizer]]. This linear polarized light is reflected by a [[beam splitter]] towards the [[Objective (optics)|objective]], which focuses the light on the specimen. The glass surface is reflective to a certain degree and will reflect the polarized light. Light that is not reflected by the glass will travel into the cell and be reflected by the cell membrane. Three situations can occur: &lt;br /&gt;
# When the membrane is close to the glass, the reflected light from the glass is shifted half of a wavelength, so that light reflected from the membrane will have a phase shift compared to the reflected light from the glass [[Phase (waves)|phases]] and therefore cancel each other out ([[Interference (wave propagation)|interference]]). This interference results in a dark pixel in the final image (the left case in the figure). &lt;br /&gt;
# When the membrane is not attached to the glass, the reflection from the membrane has a smaller phase shift compared to the reflected light from the glass, and therefore they will not cancel each other out, resulting in a bright pixel in the image (the right case in the figure). &lt;br /&gt;
# When there is no specimen, only the reflected light from the glass is detected and will appear as bright pixels in the final image.&lt;br /&gt;
&lt;br /&gt;
The reflected light will travel back to the beam splitter and pass through a second polarizer, which eliminates scattered light, before reaching the detector (usually a [[Charge-coupled device|CCD camera]]) in order to form the final picture. Note that the polarizers can increase the efficiency by reducing scattered light, however in a modern setup with a sensitive digital camera, they&amp;#039;re not required.&amp;lt;ref name=&amp;quot;Wu2009&amp;quot;/&amp;gt;&lt;br /&gt;
&lt;br /&gt;
===Mathematical theory===&lt;br /&gt;
Reflection is caused by a change in the refraction index, so on every boundary a part of the light will be reflected. The amount of reflection is given by the reflection coefficient &amp;lt;math&amp;gt;r_{12} \!&amp;lt;/math&amp;gt;, according to the following rule:&amp;lt;ref name=&amp;quot;Verschueren1985&amp;quot;/&amp;gt;{{Quote|&amp;lt;math&amp;gt;r_{12}=\frac{n_{1}-n_{2}}{n_{1}+n_{2}}&amp;lt;/math&amp;gt;}}&lt;br /&gt;
&lt;br /&gt;
Reflectivity &amp;lt;math&amp;gt;R \!&amp;lt;/math&amp;gt; is a ratio of the reflected light intensity (&amp;lt;math&amp;gt;I_r \!&amp;lt;/math&amp;gt;) and the incoming light intensity (&amp;lt;math&amp;gt;I_i \!&amp;lt;/math&amp;gt;):&amp;lt;ref name=&amp;quot;Verschueren1985&amp;quot;/&amp;gt;{{Quote|&amp;lt;math&amp;gt;R=\frac{I_{r}}{I_{i}}=\left \lbrack \frac{n_{1}-n_{2}}{n_{1}+n_{2}} \right \rbrack^2={r_{12}}^2&amp;lt;/math&amp;gt;}}&lt;br /&gt;
&lt;br /&gt;
Using typical refractive indices for glass (1.50-1.54, see [[List of refractive indices|list]]), water (1.31, see [[List of refractive indices|list]]), the cell membrane (1.48)&amp;lt;ref name=&amp;quot;refr idx&amp;quot;&amp;gt;{{Cite book |type=PhD thesis |chapter=Cell Structure |chapterurl=http://www.nmr.mgh.harvard.edu/~adunn/papers/dissertation/node7.html |title=Light scattering properties of cells |url=http://www.nmr.mgh.harvard.edu/~adunn/papers/dissertation/ |first=Andrew Kenneth |last=Dunn |year=1997 |publisher=[[University of Texas at Austin]] |accessdate=February 23, 2010 |oclc=39949488}}&amp;lt;/ref&amp;gt; and the cytosol (1.35),&amp;lt;ref name=&amp;quot;refr idx&amp;quot;/&amp;gt; one can calculate the fraction of light being reflected by each interface. The amount of reflection increases as the difference between refractive indices increases, resulting in a large reflection from the interface between the glass surface and the culture medium (about equal to water: 1.31-1.33). This means that without a cell the image will be bright, whereas when the cell is attached, the difference between medium and the membrane causes a large reflection that is slightly shifted in phase, causing interference with the light reflected by the glass. Because the amplitude of the light reflected from the medium-membrane interface is decreased due to scattering, the attached area will appear darker but not completely black. Because the cone of light focused on the sample gives rise to different angles of incident light, there is a broad range of interference patterns. When the patterns differ by less than 1 wavelength (the zero-order fringe), the patterns converge, resulting in increased intensity. This can be obtained by using an objective with a numerical aperture greater than 1.&amp;lt;ref name=&amp;quot;Verschueren1985&amp;quot;/&amp;gt;&lt;br /&gt;
&lt;br /&gt;
==Requirements==&lt;br /&gt;
In order to image cells using IRM, a microscope needs at least the following elements:&lt;br /&gt;
# a light source, such as a halogen lamp&lt;br /&gt;
# an [[optical filter]] (which passes a small range of wavelengths)&lt;br /&gt;
# a beam splitter (which reflects 50% and transmits 50% of the chosen wavelength)&lt;br /&gt;
&lt;br /&gt;
The light source needs to produce high intensity light, as a lot of light will be lost by the beam splitter and the sample itself. Different wavelengths result in different IRM images; Bereiter-Hahn and colleagues showed that for their PtK 2 cells, light with a wavelength of 546&amp;amp;nbsp;nm resulted in better contrast than blue light with a wavelength of 436&amp;amp;nbsp;nm.&amp;lt;ref name=&amp;quot;Bereiter1979&amp;quot;/&amp;gt; There have been many refinements to the basic theory of IRM, most of which increase the efficiency and yield of the image formation. By placing polarizers and a [[Wave plate|quarter wave plate]] between the beam splitter and the specimen, the linear polarized light can be converted into [[circular polarization|circular polarized light]] and afterwards be converted back to linear polarized light, which increases the efficiency of the system. The [[polarizer#Circular polarizers|circular polarizer]] article discusses this process in detail. Furthermore, by including a second polarizer, which is rotated 90° compared to the first polarizer, stray light can be prevented from reaching the detector, increasing the signal to noise ratio (see Figure 2 of Verschueren&amp;lt;ref name=&amp;quot;Verschueren1985&amp;quot;/&amp;gt;).&lt;br /&gt;
&lt;br /&gt;
==Biological applications==&lt;br /&gt;
There are several ways IRM can be used to study biological samples. Early examples of uses of the technique focused on [[cell adhesion]]&amp;lt;ref name=&amp;quot;Curtis1964&amp;quot;/&amp;gt; and [[cell migration]].&amp;lt;ref&amp;gt;{{cite journal |author=Godwin SL, Fletcher M, Burchard RP |title=Interference reflection microscopic study of sites of association between gliding bacteria and glass substrata |journal=Journal of Bacteriology |volume=171 |issue=9 |pages=4589–94 |year=1989 |month=September |pmid=2768185 |pmc=210255 |url=http://jb.asm.org/cgi/pmidlookup?view=long&amp;amp;pmid=2768185}}&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
===Vesicle fusion===&lt;br /&gt;
More recently, the technique has been used to study [[exocytosis]] in [[chromaffin cell]]s.&amp;lt;ref name=&amp;quot;Wu2009&amp;quot;&amp;gt;{{cite journal |author=Wu MM, Llobet A, Lagnado L |title=Loose coupling between calcium channels and sites of exocytosis in chromaffin cells |journal=The Journal of Physiology |volume=587 |issue=Pt 22 |pages=5377–91 |year=2009 |month=November |pmid=19752110 |doi=10.1113/jphysiol.2009.176065 |pmc=2793871}}&amp;lt;/ref&amp;gt; When imaged using DIC, chromaffin cells appear as round cells with small protrusions. When the same cell is imaged using IRM, the footprint of the cell on the glass can be clearly seen as a dark area with small protrusions (see Figure 2 in the gallery below). When vesicles fuse with the membrane, they appear as small light circles within the dark footprint (Figure 2, bright spots in the top cell in the right panel). An example of vesicle fusion in chromaffin cells using IRM is shown in movie 1. Upon stimulation with 60&amp;amp;nbsp;[[Molar concentration|mM]] [[potassium]], multiple bright spots begin to appear inside the dark footprint of the chromaffin cell as a result of exocytosis of [[Large dense core vesicle|dense core granules]]. Because IRM doesn&amp;#039;t require a fluorescent label, it can be combined with other imaging techniques, such as [[Fluorescence microscope|epifluorescence]] and TIRF microscopy to study protein dynamics together with vesicle exocytosis and endocytosis. Another benefit of the lack of fluorescent labels is reduced [[phototoxicity]].&lt;br /&gt;
&lt;br /&gt;
&amp;lt;gallery&amp;gt;&lt;br /&gt;
Image:Chromaffin cell imaged with DIC and IRM.png|&amp;#039;&amp;#039;&amp;#039;Fig. 2&amp;#039;&amp;#039;&amp;#039;: Two chromaffin cells imaged with DIC (left) and IRM (right).&lt;br /&gt;
File:IRM_LDCV_fusion_after_high_K.ogg|&amp;#039;&amp;#039;&amp;#039;Movie 1&amp;#039;&amp;#039;&amp;#039;: Vesicle fusion visualized using IRM. Scale bar represents 2&amp;amp;nbsp;μm.&lt;br /&gt;
&amp;lt;/gallery&amp;gt;&lt;br /&gt;
&lt;br /&gt;
==References==&lt;br /&gt;
{{reflist}}&lt;br /&gt;
&lt;br /&gt;
==External links==&lt;br /&gt;
* [http://www.einstein.yu.edu/aif/instructions/irm/index.htm Albert Einstein College of Medicine on IRM]&lt;br /&gt;
* [http://www.microscopyu.com/articles/confocal/reflectedconfocalintro.html Reflected confocal microscopy on Nikon MicroscopyU]&lt;br /&gt;
&lt;br /&gt;
[[Category:Microscopy]]&lt;/div&gt;</summary>
		<author><name>en&gt;Bender235</name></author>
	</entry>
</feed>