Hello and welcome. My title is Figures Wunder. His family members lives in South Dakota but his spouse desires them to transfer. I am a meter reader but I strategy on changing it. One of the extremely best things in the world for him is to gather badges but he is having difficulties to find time for it.<br><br>Here is my page; [http://theoffshoremanual.com/?testimonial=know-facing-candida-albicans std testing at home]
'''Dilution''' is a reduction in the [[Ph]] of a chemical (gas, vapor, solution).  It is the process of decreasing the concentration of a [[solution|solute]] in [[solution]], usually simply by mixing with more [[solvent]].  To dilute a solution means to add more solvent without the addition of more solute. The resulting solution is thoroughly mixed so as to ensure that all parts of the solution are identical.
 
The same [[direct relationship]] applies to [[gas]]es and [[vapor]]s diluted in air for example. Although, thorough mixing of gases and vapors may not be as easily accomplished.
 
For example, if there are 10 grams of salt (the solute) dissolved in  1 litre of water (the solvent), this solution has a certain salt concentration/[[molarity]]. If one adds 1 litre of water to this solution the salt concentration is reduced. The diluted solution still contains 10 grams of salt/(0.171 [[Mole (unit)|mole]]s of [[NaCl]]).
 
Mathematically this relationship can be shown in the [[equation]]:
 
:<math> C_1\times V_1 = C_2\times V_2 </math>
 
Where:
 
:<math>C_1 = </math> Initial concentration or molarity.
 
:<math>V_1 = </math> Initial volume.
 
:<math>C_2 = </math> Final concentration or molarity.
 
:<math>V_2 = </math> Final volume
 
==Basic Room Purge Equation==
The ''Basic Room Purge Equation'', is used in [[industrial hygiene]].  It determines the time required to reduce a known [[vapor concentration]] existing in a  closed space to a lower vapor concentration.  The equation can only be applied when the purged volume of vapor or gas is replaced with "clean" air or gas. For example, the equation can be used to calculate the time required at a certain ventilation rate to reduce a high [[carbon monoxide]] concentration in a room.
 
:<math>\ D_t=\left [ \frac{V}{Q} \right ] \cdot ln\left [ \frac{C_{initial}}{C_{ending}}\right ] \quad </math>
 
Sometimes the equation is also written as:
 
:<math>\ ln\left [ \frac{C_{ending}}{C_{initial}}\right ] \quad={-}\frac{Q}{V} \cdot (t_{ending}-t_{initial})\quad  </math>          where <math>t_{initial} = 0</math>
 
<math>D_t =</math> Time required; the unit of time used is the same as is used for <math>Q</math>.  
 
<math>V =</math> Air or gas volume of the closed space or room in cubic feet, cubic meters or [[liter]]s
 
<math>Q =</math> Ventilation rate into or out of the room in [[cubic feet per minute]], cubic meters per hour or [[Cubic metre per second|liters per second]]
 
<math>C_{initial} =</math> Initial concentration of a vapor inside the room measured in [[Parts per million|ppm]]
 
<math>C_{ending} =</math> Final reduced concentration of the vapor inside the room in ppm
 
==Dilution Ventilation Equation==
The ''Basic Room Purge Equation'' can be used only for purge scenarios.  In a scenario where a liquid continuously evaporates from a container in a ventilated room, a [[differential equation]] has to be used.
 
:<math> {dC \over dt} = \frac{G - Q' C}{V}</math>
 
Where the ventilation rate has been adjusted by a mixing factor K.
:<math> Q' = \frac{Q}{K}</math>
 
<math>C =</math> concentration of a gas
<math>G =</math> generation rate
 
<math>V =</math> room volume
 
<math>Q' =</math> adjusted ventilation rate of the volume
 
==Welding==
The dilution in welding terms is defined as the weight of the base metal melted divided by the total weight of the weld metal. For example, if we have a dilution of 0.40, the fraction of the weld metal that came from the consumable electrode is 0.60.
 
==See also==
*[[Displacement ventilation]]
*[[Reaction rate]]
*[[Partial molar quantities]]
*[[Apparent molar property]]
*[[Excess molar quantity]]
 
==External links==
* [http://pubs.acs.org/doi/abs/10.1021/ja01320a004]
 
{{DEFAULTSORT:Dilution (Equation)}}
[[Category:Equations]]
[[Category:Chemical engineering]]

Latest revision as of 13:00, 20 October 2013

Dilution is a reduction in the Ph of a chemical (gas, vapor, solution). It is the process of decreasing the concentration of a solute in solution, usually simply by mixing with more solvent. To dilute a solution means to add more solvent without the addition of more solute. The resulting solution is thoroughly mixed so as to ensure that all parts of the solution are identical.

The same direct relationship applies to gases and vapors diluted in air for example. Although, thorough mixing of gases and vapors may not be as easily accomplished.

For example, if there are 10 grams of salt (the solute) dissolved in 1 litre of water (the solvent), this solution has a certain salt concentration/molarity. If one adds 1 litre of water to this solution the salt concentration is reduced. The diluted solution still contains 10 grams of salt/(0.171 moles of NaCl).

Mathematically this relationship can be shown in the equation:

C1×V1=C2×V2

Where:

C1= Initial concentration or molarity.
V1= Initial volume.
C2= Final concentration or molarity.
V2= Final volume

Basic Room Purge Equation

The Basic Room Purge Equation, is used in industrial hygiene. It determines the time required to reduce a known vapor concentration existing in a closed space to a lower vapor concentration. The equation can only be applied when the purged volume of vapor or gas is replaced with "clean" air or gas. For example, the equation can be used to calculate the time required at a certain ventilation rate to reduce a high carbon monoxide concentration in a room.

Dt=[VQ]ln[CinitialCending]

Sometimes the equation is also written as:

ln[CendingCinitial]=QV(tendingtinitial) where tinitial=0

Dt= Time required; the unit of time used is the same as is used for Q.

V= Air or gas volume of the closed space or room in cubic feet, cubic meters or liters

Q= Ventilation rate into or out of the room in cubic feet per minute, cubic meters per hour or liters per second

Cinitial= Initial concentration of a vapor inside the room measured in ppm

Cending= Final reduced concentration of the vapor inside the room in ppm

Dilution Ventilation Equation

The Basic Room Purge Equation can be used only for purge scenarios. In a scenario where a liquid continuously evaporates from a container in a ventilated room, a differential equation has to be used.

dCdt=GQCV

Where the ventilation rate has been adjusted by a mixing factor K.

Q=QK

C= concentration of a gas

G= generation rate

V= room volume

Q= adjusted ventilation rate of the volume

Welding

The dilution in welding terms is defined as the weight of the base metal melted divided by the total weight of the weld metal. For example, if we have a dilution of 0.40, the fraction of the weld metal that came from the consumable electrode is 0.60.

See also

External links